Genset Main Technical Dat
Generator Model | JGC24GF |
Prime power | 24KW |
Standby power | 26.4KW |
Voltage | 400V/230V |
Frequency | 50HZ/1500 rpm |
Power factor | 0.8(lag) |
Governor type | Electric |
Prime Power : Prime power is available for an unlimited number of annual hours in variable load application, in accordance with GB/T2820-97; A 10% overload capability is available for a period of 1 hour within a 12-hour period of operation. Standby Power Rating : The standby power rating is applicable for supplying emergency power for the duration of a utility power interruption. No overload, utility parallel or negotiated outage operation capability is available at this rating. Voltage regulation Voltage regulation maintained within ±0.5% as follow:Power factor Between 0.8~1.0 lag From no load to full load, any steady loadSpeed droop variation under 4.5% Frequency/Speed undulationChange load from 0-100%, Frequency/Speed Droop Ratio within 5%Load from 25-100%, any steady load Frequency/Speed undulation within 0.25% Effect factor of telecom Telephone Influence Factor (TIF): Less than 50 THF : Less than 2% Cummins Diesel Engine Technical Data
Engine Model | 4BT3.9-G2 |
Configuration | 4 cycle , 4 cylinders in line |
Aspiration | Turbocharged |
Bore×Stroke | 102 x120 mm |
Rated speed | 1500rpm |
Displacement | 3.9 L |
Compression Ratio | 16.5:1 |
Prime Power | 36KW |
Speed Governor | electrical |
Cooling System | Water-cooled , 40℃ Radiator As Standard |
Speed Stability (%) | ≤5% |
Fuel Consumption at 100% Load | 218g/kw.h |
Starter Motor | DC24V, |
Contact us if you need more details on Motor Generator. We are ready to answer your questions on packaging, logistics, certification or any other aspects about Marine Motor Generator、Jiangsu New Magnetic Motor Generator for Sale. If these products fail to match your need, please contact us and we would like to provide relevant information.
Product Categories : Marine products > Marine Generator